PRODUCT CENTER
Products
KSD314 45A Big Current Thermostat
PRODUCT DESCRIPTION
KSD314 series is a type of bimetal thermostat with housing(3/4" disc), work in the resistance loading. The internal current-carrying parts are all welded, with high loading capacity, the max rated current up to 45A, It is suitable for temperature control and protection in big power appliances.
According to different structures and service purposes, KSD314 series is divided into seven sub-series as: KSD314-V, KSD314-R, KSD314-R-C, KSD314-N, KSD314-T, KSD314-Q, KSD314-F.
BASIC TECHNICAL PARAMETERS
Sub-series |
Action type |
Switch type |
Rated current (resistive load) |
Operating temperature OT. |
KSD314-V |
Auto reset |
SPST、NC/NO |
35A |
30~180°C(TUV)30~140°C(UL) |
KSD314-R & KSD314-R-C |
Manual reset |
SPST、NC |
35A |
40~140°C |
KSD314-N |
SOD |
SPST、NC |
35A |
40~140°C |
KSD314-T |
PTC cutoff,Voltage maintain type |
SPST、NC |
35A |
55~140°C |
KSD314-Q |
Double functions-Auto reset and one shot type |
SPST、NC |
45A |
30~100°C |
KSD314-F (developing) |
SPDT type Auto reset |
SPDT |
25A |
30~140°C |
KSD314-W (developing) |
Auto reset with thermal compensation |
SPST、NC |
25A |
30~140°C |
DIMENSION OF THE MAIN BODY
INSTALLATION AND DIRECTION FOR USE
Installation and use instructions: |
1. Grounding method: Connected to the grounding metal parts of the equipment through the metal casing of the thermostat. 2. The thermostat shall be operated in a general indoor environment where the relative humidity of the air is not more than 90%, no corrosive gas, no flammable gas and conductive dust. 3. When the temperature controller is in contact with the temperature, the cover should be placed close to the heat-generating part of the controlled appliance, and the thermal surface of the cover should be coated with thermal grease or other similar heat-conducting medium. 4. When the temperature controller is exposed to liquid or steam, it is recommended to use a stainless steel cover and a reliable leak-proof measure to prevent liquid from seeping into the insulation of the thermostat. 5. It is not possible to collapse or deform the top of the cover to avoid changes in operating temperature or other properties. 6. Do not allow liquid to penetrate inside the thermostat! The housing must be protected from excessive forces to prevent cracking; the housing should be kept clean to prevent contamination of conductive materials to prevent short-circuit breakdown due to reduced insulation. 7. The terminal cannot be bent during use, otherwise the reliability of the electrical connection will be affected. |